<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article">
	<front>
		<journal-meta>
			<journal-id journal-id-type="publisher-id">INFORMATICA</journal-id>
			<journal-title-group>
				<journal-title>Informatica</journal-title>
			</journal-title-group>
			<issn pub-type="epub">0868-4952</issn>
			<issn pub-type="ppub">0868-4952</issn>
			<publisher>
				<publisher-name>VU</publisher-name>
			</publisher>
		</journal-meta>
		<article-meta>
			<article-id pub-id-type="publisher-id">inf14409</article-id>
			<article-id pub-id-type="doi">10.15388/Informatica.2003.039</article-id>
			<article-categories>
				<subj-group subj-group-type="heading">
					<subject>Research article</subject>
				</subj-group>
			</article-categories>
			<title-group>
				<article-title>Evaluation of Ultrasound Attenuation Characteristics of Human Cataract</article-title>
			</title-group>
			<contrib-group>
				<contrib contrib-type="Author">
					<name>
						<surname>Paunksnis</surname>
						<given-names>Alvydas</given-names>
					</name>
					<email xlink:href="mailto:apaun@medi.lt">apaun@medi.lt</email>
					<xref ref-type="aff" rid="j_INFORMATICA_aff_000"/>
				</contrib>
				<contrib contrib-type="Author">
					<name>
						<surname>Kurapkienė</surname>
						<given-names>Skaidra</given-names>
					</name>
					<xref ref-type="aff" rid="j_INFORMATICA_aff_000"/>
				</contrib>
				<aff id="j_INFORMATICA_aff_000">Department of Ophthalmology, Institute for Biomedical Research, Kaunas University of Medicine, Eiveniu 4, LT‐3007, Kaunas, Lithuania</aff>
			</contrib-group>
			<contrib-group>
				<contrib contrib-type="Author">
					<name>
						<surname>Mačiulis</surname>
						<given-names>Audris</given-names>
					</name>
					<email xlink:href="mailto:maciul@ktu.lt">maciul@ktu.lt</email>
					<xref ref-type="aff" rid="j_INFORMATICA_aff_001"/>
				</contrib>
				<aff id="j_INFORMATICA_aff_001">Department of Applied Electronics, Kaunas University of Technology, Studentų 50‐302, LT‐3031, Kaunas, Lithuania</aff>
			</contrib-group>
			<contrib-group>
				<contrib contrib-type="Author">
					<name>
						<surname>Paunksnienė</surname>
						<given-names>Marija‐Liucija</given-names>
					</name>
					<email xlink:href="mailto:oftalmolog@lva.lt">oftalmolog@lva.lt</email>
					<xref ref-type="aff" rid="j_INFORMATICA_aff_002"/>
				</contrib>
				<aff id="j_INFORMATICA_aff_002">Department of Anatomy and Histology, Lithuanian Veterinary Academy</aff>
			</contrib-group>
			<pub-date pub-type="epub">
				<day>01</day>
				<month>01</month>
				<year>2003</year>
			</pub-date>
			<volume>14</volume>
			<issue>4</issue>
			<fpage>529</fpage>
			<lpage>540</lpage>
			<history>
				<date date-type="received">
					<day>01</day>
					<month>07</month>
					<year>2003</year>
				</date>
			</history>
			<abstract>
				<p>Cataract is very frequent disease of human eye and the diagnosis of this disease is not difficult. However, it is important to describe it quantitatively, but it is difficult using only the slit lamp. Ultrasound examinations are widely used in ophthalmology. Piezoelectric crystals generate ultrasound waves of 5–50 MHz. Short pulses of 2 to 3 cycles are sent from transducer into the eye. These pulses go through the tissues of the eye with the speed that is inversely proportional to the density and elasticity of the eye. Acoustic parameters of biologic tissues are described by velocity and attenuation coefficient. It is known that in soft tissues the attenuation coefficient is approximately proportional to the frequency – high frequency components of echoes are attenuated more than the lower frequency components. Results of ultrasound attenuation characteristics of human nuclear cataract are presented. It was shown that ultrasound attenuation of nuclear cataract could be used as “second opinion” for physicians decision support.</p>
			</abstract>
			<kwd-group>
				<label>Keywords</label>
				<kwd>ultrasound attenuation</kwd>
				<kwd>nuclear and diabetic cataract</kwd>
				<kwd>acoustic parameters</kwd>
				<kwd>digital signal processing</kwd>
			</kwd-group>
		</article-meta>
	</front>
</article>