<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd"><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article"><front><journal-meta><journal-id journal-id-type="publisher-id">INFORMATICA</journal-id><journal-title-group><journal-title>Informatica</journal-title></journal-title-group><issn pub-type="epub">0868-4952</issn><issn pub-type="ppub">0868-4952</issn><publisher><publisher-name>VU</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">inf22408</article-id><article-id pub-id-type="doi">10.15388/Informatica.2011.344</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research article</subject></subj-group></article-categories><title-group><article-title>Optimization-Based Evaluation of Concentrations in Modeling the Biosensor-Aided Measurement</article-title></title-group><contrib-group><contrib contrib-type="Author"><name><surname>Žilinskas</surname><given-names>Antanas</given-names></name><email xlink:href="mailto:antanas.zilinskas@mii.vu.lt">antanas.zilinskas@mii.vu.lt</email><xref ref-type="aff" rid="j_INFORMATICA_aff_000"/></contrib><contrib contrib-type="Author"><name><surname>Baronas</surname><given-names>Darius</given-names></name><email xlink:href="mailto:darius.baronas@mif.vu.lt">darius.baronas@mif.vu.lt</email><xref ref-type="aff" rid="j_INFORMATICA_aff_001"/></contrib><aff id="j_INFORMATICA_aff_000">Vilnius University, Faculty of Mathematics and Informatics, Naugarduko 24, LT-03225 Vilnius, Lithuania</aff><aff id="j_INFORMATICA_aff_001">Vilnius University, Institute of Mathematics and Informatics, Akademijos 4, LT-08663 Vilnius, Lithuania</aff></contrib-group><pub-date pub-type="epub"><day>01</day><month>01</month><year>2011</year></pub-date><volume>22</volume><issue>4</issue><fpage>589</fpage><lpage>600</lpage><history><date date-type="received"><day>01</day><month>09</month><year>2011</year></date><date date-type="accepted"><day>01</day><month>12</month><year>2011</year></date></history><abstract><p>The concentration of a substrate in a solution can be measured using amperometric signals of biosensors: in fact the maximum (steady state) current is measured which is calibrated in the units of concentration. Such a simple method is not applicable in the case of several substrates. In the present paper, the problem of evaluation of concentrations of several substrates is tackled by minimizing the discrepancy between the observed and modeled transition processes of the amperometric signal.</p></abstract><kwd-group><label>Keywords</label><kwd>optimization</kwd><kwd>modeling</kwd><kwd>biosensor</kwd><kwd>concentration measurement</kwd></kwd-group></article-meta></front></article>